Calibration init ======================= CALIBRATION_INIT code is 0x53 Enters lock into calibration process of unlocked and locked positions. Input parameters ---------------- none Result ------ +-----------------+-----------+--------------------------------+ | **Result name** | **Value** | **Description** | +-----------------+-----------+--------------------------------+ | SUCCESS | 0x00 | Command accepted. | +-----------------+-----------+--------------------------------+ | ERROR | 0x02 | | Command rejected. | | | | | Lock is not mounted | +-----------------+-----------+--------------------------------+ | BUSY | 0x03 | | Command rejected. | | | | | Lock is performing operation | +-----------------+-----------+--------------------------------+ Output parameters ----------------- none Example ------- 1. Form message for encryption, +-------------------+ | **Command Value** | +-------------------+ | 0x53 | +-------------------+ 2. :doc:`Encrypt <../../ptls/secured_communication>` prepared message, 3. Send it on :ref:`API commands characteristic `, 4. Receive response on :ref:`API commands characteristic `, 5. :doc:`Decrypt <../../ptls/secured_communication>` received response discarding :ref:`first header byte `, 6. Parse response +----------------+ | **Result** | +----------------+ | 0x00 (SUCCESS) | +----------------+